| COMPARE | PART NUMBER | PACKAGE | Repetitive peak reverse voltage(V) | Average rectified output current(A) | Forward voltage per diode(V) | Non-repetitive surge current(A) | DATASHEET |
|---|---|---|---|---|---|---|---|
| GBJH5010 Standard bridge rectifiers | GBJ-H | 1000RatingConditionsRepetitive peak reverse voltage, VRRM. | 50RatingConditionsWith heatsink at 100 °C; see datasheet derating curve. Without heatsink: 5.2 A at 25 °C. | 1.1MaximumConditionsIF = 25 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 400RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| GBU3516 Standard bridge rectifiers | GBU | 1600RatingConditionsRepetitive peak reverse voltage, VRRM. | 35RatingConditionsWith heatsink at 100 °C, mounted on a 250 × 250 × 2 mm aluminum plate (note 2). Without heatsink: 4.2 A at 100 °C. | 1.15MaximumConditionsIF = 17.5 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 350RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| GBJ2012 Standard bridge rectifiers | GBJ | 1200RatingConditionsRepetitive peak reverse voltage, VRRM. | 20RatingConditionsWith heatsink at 100 °C; see datasheet derating curve. Without heatsink: 4.1 A at 25 °C. | 1MaximumConditionsIF = 10 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 260RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| 2W10 Standard bridge rectifiers | WOB | 1000RatingConditionsRepetitive peak reverse voltage, VRRM. | 2RatingConditionsSee the forward-current derating curve and load conditions in the datasheet. | 1MaximumConditionsIF = 2 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 60RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| LDB10M Standard bridge rectifiers | LDB-S | 1000RatingConditionsRepetitive peak reverse voltage, VRRM. | 10RatingConditionsMounted on a 250 × 250 × 2 mm aluminum plate heatsink (datasheet note 2). | 1MaximumConditionsIF = 5 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 180RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| KBP310 Standard bridge rectifiers | KBP | 1000RatingConditionsRepetitive peak reverse voltage, VRRM. | 3RatingConditionsSee the forward-current derating curve and load conditions in the datasheet. | 1.05MaximumConditionsIF = 3 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 55RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| SBL8010 Standard bridge rectifiers | SBL | 1000RatingConditionsRepetitive peak reverse voltage, VRRM. | 8RatingConditionsSee the forward-current derating curve and load conditions in the datasheet. | 1MaximumConditionsIF = 4 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 220RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| SBL5010 Standard bridge rectifiers | SBL | 1000RatingConditionsRepetitive peak reverse voltage, VRRM. | 5RatingConditionsSee the forward-current derating curve and load conditions in the datasheet. | 1MaximumConditionsIF = 2.5 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 200RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| DB157S Standard bridge rectifiers | DBS | 1000RatingConditionsRepetitive peak reverse voltage, VRRM. | 1.5RatingConditionsSee the forward-current derating curve and load conditions in the datasheet. | 1MaximumConditionsIF = 1.5 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 60RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| YBS3010 Standard bridge rectifiers | TMBF | 1000RatingConditionsRepetitive peak reverse voltage, VRRM. | 3RatingConditionsSee the forward-current derating curve and load conditions in the datasheet. | 1MaximumConditionsIF = 3 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 120RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| YBS3006 Standard bridge rectifiers | TMBF | 600RatingConditionsRepetitive peak reverse voltage, VRRM. | 3RatingConditionsSee the forward-current derating curve and load conditions in the datasheet. | 1MaximumConditionsIF = 3 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 120RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| MB10F Standard bridge rectifiers | MBF | 1000RatingConditionsRepetitive peak reverse voltage, VRRM. | 1RatingConditionsSee the forward-current derating curve and load conditions in the datasheet. | 1MaximumConditionsIF = 1 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 30RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| MB10S Standard bridge rectifiers | MBS | 1000RatingConditionsRepetitive peak reverse voltage, VRRM. | 1RatingConditionsSee the forward-current derating curve and load conditions in the datasheet. | 1MaximumConditionsIF = 1 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 30RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| ABS10 Standard bridge rectifiers | ABS | 1000RatingConditionsRepetitive peak reverse voltage, VRRM. | 1RatingConditionsSee the forward-current derating curve and load conditions in the datasheet. | 1MaximumConditionsIF = 1 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 30RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| ABS8 Standard bridge rectifiers | ABS | 800RatingConditionsRepetitive peak reverse voltage, VRRM. | 1RatingConditionsSee the forward-current derating curve and load conditions in the datasheet. | 1MaximumConditionsIF = 1 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 30RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. | ||
| ABS6 Standard bridge rectifiers | ABS | 600RatingConditionsRepetitive peak reverse voltage, VRRM. | 1RatingConditionsSee the forward-current derating curve and load conditions in the datasheet. | 1MaximumConditionsIF = 1 A; TA = 25 °C; per diode. Pulse test: 300 µs, 1% duty cycle. | 30RatingConditions8.3 ms single half-sine wave superimposed on rated load; per diode. |