Skip to content

Find a product

Type a part number or package to search the catalog.

Browse the full catalog

PRODUCT SELECTION

Fast recovery bridge rectifiers

Single-phase fast recovery bridges in surface-mount and through-hole packages. Typical and maximum reverse recovery times are listed separately; a blank maximum means the datasheet does not specify it in the maximum column. Check load, temperature and heatsink conditions when comparing current ratings.

Product selector

Fast recovery bridge rectifiers

Fast recovery bridge rectifiers

Compare products

Values may use different test conditions. Review the conditions and original datasheets before choosing a component. A dash means no published value.

Scroll across to see all selected products and down for more specifications.

Selected products, specifications, test conditions and datasheets.

5 products found

Scroll horizontally to view all parameters and conditions.

Fast recovery bridge rectifiers specifications, including test conditions and datasheet downloads.
PART NUMBERPACKAGERepetitive peak reverse voltage(V)Average rectified output current(A)Non-repetitive surge current(A)Reverse recovery time (trr), max(ns)Reverse recovery time (trr), typ(ns)Forward voltage per diode(V)DATASHEET
RHBL15M

Fast recovery bridge rectifiers

HBL1000Maximum
Conditions

Maximum repetitive peak reverse voltage; TA = 25 °C unless otherwise specified.

15Maximum
Conditions

TA = 25 °C unless otherwise specified in the rating table; see the TC derating curve on p. 2 and thermal conditions. Single-phase, half-wave, 60 Hz, resistive or inductive load; derate current by 20% for a capacitive load.

320Maximum
Conditions

8.3 ms single half sine-wave superimposed on rated load; TA = 25 °C unless otherwise specified. See the p. 2 surge curve.

500Maximum
Conditions

IF = 0.5 A; IR = 1.0 A; IRR = 0.25 A; TA = 25 °C.

200Typical
Conditions

IF = 0.5 A; IR = 1.0 A; IRR = 0.25 A; TA = 25 °C.

1.3Maximum
Conditions

Per diode; IF = 7.5 A; TA = 25 °C. Pulse test: 300 µs pulse width, 1% duty cycle.

PDF
RGBU406

Fast recovery bridge rectifiers

GBU600Maximum
Conditions

Maximum repetitive peak reverse voltage; TA = 25 °C unless otherwise specified.

4Maximum
Conditions

With heatsink at 100 °C; TC identified in the p. 2 derating curve. Note 2: device mounted on a 250 mm × 250 mm × 2.0 mm aluminum plate heatsink. Single-phase, half-wave, 60 Hz, resistive or inductive load; derate current by 20% for a capacitive load.

135Maximum
Conditions

8.3 ms single half sine-wave superimposed on rated load; TA = 25 °C unless otherwise specified. See the p. 2 surge curve.

350Maximum
Conditions

IF = 0.5 A; IR = 1.0 A; IRR = 0.25 A; TA = 25 °C.

220Typical
Conditions

IF = 0.5 A; IR = 1.0 A; IRR = 0.25 A; TA = 25 °C.

0.98Maximum
Conditions

Per diode; IF = 4 A; TA = 25 °C. Pulse test: 300 µs pulse width, 1% duty cycle.

PDF
RGBJ2510

Fast recovery bridge rectifiers

GBJ1000Maximum
Conditions

Maximum repetitive peak reverse voltage; TA = 25 °C unless otherwise specified.

25Maximum
Conditions

With heatsink at 100 °C; TC identified in the p. 2 derating curve. Refer to the datasheet thermal and mounting conditions. Single-phase, half-wave, 60 Hz, resistive or inductive load; derate current by 20% for a capacitive load.

300Maximum
Conditions

8.3 ms single half sine-wave superimposed on rated load; TA = 25 °C unless otherwise specified. See the p. 2 surge curve.

—200Typical
Conditions

IF = 0.5 A; IR = 1.0 A; IRR = 0.25 A; TA = 25 °C. Listed in the Typ. column; the Max. column is blank.

1.1Maximum
Conditions

Per diode; IF = 12.5 A; TA = 25 °C. Pulse test: 300 µs pulse width, 1% duty cycle.

PDF
RB307S

Fast recovery bridge rectifiers

DBS1000Maximum
Conditions

Maximum repetitive peak reverse voltage; TA = 25 °C unless otherwise specified.

3Maximum
Conditions

TC = 100 °C, as specified in the current-rating row; see the datasheet mounting and derating information. Single-phase, half-wave, 60 Hz, resistive or inductive load; derate current by 20% for a capacitive load.

85Maximum
Conditions

8.3 ms single half sine-wave superimposed on rated load; TA = 25 °C unless otherwise specified. See the p. 2 surge curve.

500Maximum
Conditions

IF = 0.5 A; IR = 1.0 A; IRR = 0.25 A; TA = 25 °C.

—1.25Maximum
Conditions

Per diode; IF = 3 A; TA = 25 °C. Pulse test: 300 µs pulse width, 1% duty cycle.

PDF
RABS10

Fast recovery bridge rectifiers

ABS1000Maximum
Conditions

Maximum repetitive peak reverse voltage; TA = 25 °C unless otherwise specified.

1Maximum
Conditions

TA = 25 °C unless otherwise specified. Note 2: device mounted on a 250 mm × 250 mm × 2.0 mm aluminum plate heatsink. Single-phase, half-wave, 60 Hz, resistive or inductive load; derate current by 20% for a capacitive load.

30Maximum
Conditions

8.3 ms single half sine-wave superimposed on rated load; TA = 25 °C unless otherwise specified. See the p. 2 surge curve.

500Maximum
Conditions

IF = 0.5 A; IR = 1.0 A; IRR = 0.25 A; TA = 25 °C.

200Typical
Conditions

IF = 0.5 A; IR = 1.0 A; IRR = 0.25 A; TA = 25 °C.

1.3Maximum
Conditions

Per diode; IF = 1 A; TA = 25 °C. Pulse test: 300 µs pulse width, 1% duty cycle.

PDF

LET'S DISCUSS YOUR APPLICATION

Find the right starting point.

Explore the catalog or share your component requirements.

Contact our team