PRODUCT SELECTION
Three-phase bridge rectifiers
Six-diode bridge rectifiers with three AC terminals and positive and negative DC terminals. The SGBJ35 series covers 1000 V, 1200 V and 1600 V repetitive reverse-voltage ratings. Current ratings retain the source datasheet load, temperature and heatsink conditions.
Product selector
Three-phase bridge rectifiers
Select 2–4 products in this category to compare.
Part number, package and datasheet columns always remain visible.
Choose columns
3 products found
Scroll horizontally to view all parameters and conditions.
| COMPARE | PART NUMBER | PACKAGE | Repetitive peak reverse voltage(V) | Average rectified output current(A) | Non-repetitive surge current(A) | DATASHEET |
|---|---|---|---|---|---|---|
| SGBJ3516 Three-phase bridge rectifiers | SGBJ | 1600MaximumConditionsMaximum repetitive peak reverse voltage; TA = 25 °C unless otherwise specified. | 35MaximumConditionsWith heatsink at 110 °C; TC identified in the p. 2 derating curve. The source datasheet states a single-phase, half-wave, 60 Hz, resistive or inductive load test condition and 20% current derating for a capacitive load. Refer to the complete datasheet for use in a three-phase circuit. | 400MaximumConditionsPer diode; 8.3 ms single half sine-wave superimposed on rated load; TA = 25 °C unless otherwise specified. | ||
| SGBJ3512 Three-phase bridge rectifiers | SGBJ | 1200MaximumConditionsMaximum repetitive peak reverse voltage; TA = 25 °C unless otherwise specified. | 35MaximumConditionsWith heatsink at 110 °C; TC identified in the p. 2 derating curve. The source datasheet states a single-phase, half-wave, 60 Hz, resistive or inductive load test condition and 20% current derating for a capacitive load. Refer to the complete datasheet for use in a three-phase circuit. | 400MaximumConditionsPer diode; 8.3 ms single half sine-wave superimposed on rated load; TA = 25 °C unless otherwise specified. | ||
| SGBJ3510 Three-phase bridge rectifiers | SGBJ | 1000MaximumConditionsMaximum repetitive peak reverse voltage; TA = 25 °C unless otherwise specified. | 35MaximumConditionsWith heatsink at 110 °C; TC identified in the p. 2 derating curve. The source datasheet states a single-phase, half-wave, 60 Hz, resistive or inductive load test condition and 20% current derating for a capacitive load. Refer to the complete datasheet for use in a three-phase circuit. | 400MaximumConditionsPer diode; 8.3 ms single half sine-wave superimposed on rated load; TA = 25 °C unless otherwise specified. |