1000 V, 1 A general-purpose rectifier diode in a DO-41 package.
Repetitive peak reverse voltage
1000 V
Maximum
Conditions
TA = 25 °C unless otherwise specified; maximum repetitive peak reverse voltage.
IF(AV), per diode
1 A
Maximum
Conditions
Single-phase, half-wave, 60 Hz, resistive or inductive load; derate current by 20% for a capacitive load. TA = 25 °C unless otherwise specified.
Forward voltage per diode
1.1 V
Maximum
Conditions
IF = 1 A; TA = 25 °C. Pulse test: 300 µs pulse width, 1% duty cycle.
Product status: MP
PRODUCT OVERVIEW
A closer look at 1N4007.
1000 V, 1 A general-purpose rectifier diode in a DO-41 package.
- Single-diode rectifier in a DO-41 package.
- Part of the 1N4001–1N4007 general-purpose rectifier series.
Technical specifications
- Repetitive peak reverse voltage
1000 VMaximum
TA = 25 °C unless otherwise specified; maximum repetitive peak reverse voltage.
Datasheet p. 1- IF(AV), per diode
1 AMaximum
Single-phase, half-wave, 60 Hz, resistive or inductive load; derate current by 20% for a capacitive load. TA = 25 °C unless otherwise specified.
Datasheet p. 1- Forward voltage per diode
1.1 VMaximum
IF = 1 A; TA = 25 °C. Pulse test: 300 µs pulse width, 1% duty cycle.
Datasheet p. 1- Non-repetitive surge current
30 AMaximum
8.3 ms single half sine-wave superimposed on rated load; TA = 25 °C unless otherwise specified.
Datasheet p. 1- Reverse leakage current
10 µAMaximum
TA = 25 °C; VR = VRRM.
Datasheet p. 1- Junction temperature range
-55 to 150 °CRange
Operating junction temperature range.
Datasheet p. 1- Diode configuration
Single
Single diode; anode and cathode shown in the p. 1 diagram.
Datasheet p. 1
Values apply under their stated conditions. The datasheet includes the complete ratings, curves and package information.